FRP Structural Section Properties

FRP Structural Sections Properties

The values below are from tests performed in accordance with ASTM


MECHANICAL PROPERTIES


ASTM


UNITS


APPROX. VALUES


Tensile Stress L


D-638


MPa


207


Tensile Stress C


D-638


MPa


48


Tensile Modulus L


D-638


GPa


17


Tensile Modulus C


D-638


GPa


5.5


Compressive Stress L


D-695


MPa


207


Compressive Stress C


D-695


MPa


103


Compressive Modulus L


D-695


GPa


17


Compressive Modulus C


D-695


GPa


7


Flexural Stress L


D-790


MPa


207


Flexural Stress C


D-790


MPa


69


Flexural Modulus L


D-790


GPa


12


Flexural Modulus C


D-790


GPa


5.5


Modulus of Elasticity E


Full Section


GPa


19


Shear Modulus

 


GPa


3


Short Beam Shear


D-2344


MPa


31


Punch Shear


D-732


MPa


69


Bearing Stress L


D-953


MPa


207


Notched Izod Impact L


D-256


J/mm


1.3


Notched Izod Impact C


D-256


J/mm


0.2


PHYSICAL PROPERTIES

 


Barcol Hardness


D-2583

 


45


24 Hour Water Absorption


D-570


% max


0.5


Density


D-792


kg/m
3


1700 – 1900


Coefficient of Thermal
Expansion L


D-696


10
0 cm/cm/0C


8


ELECTRICAL PROPERTIES

 


Arc Resistance L


D-495


Seconds


120


Dielectric Strength L


D-149


KV/mm


1.4


Dielectric Strength P


D-149


KV/mm


8


Dielectric Constant P


D-150


@50hz


5

 


Vinyl Ester and Isophthalic Polyester Structural Sections


FLAMMABILITY PROPERTIES

 


Tunnel Test


E-84


Flame spread


25 max


Flammability


D-635

 


Non-Burning

L = Lengthwise      C = Crosswise      P = Perpendicular to Face

IMPORTANT NOTE: Designers should confirm the section properties and apply appropriate load and safety factors